Welcome to our websites!

Short Lead Time for Water Pressure Switch - AC compressor trinary low high pressure switch with wire – Anxin

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our mission will be to become an innovative supplier of high-tech digital and communication devices by furnishing benefit added structure, world-class manufacturing, and service capabilities for Vanair Pressure Switch, Electronic Pressure Sensor, Compressor Pressure Switch, Special emphasis on the packaging of products to avoid any damage during transportation,Detailed attention to the valuable feedback and suggestions of our esteemed clients.
Short Lead Time for Water Pressure Switch - AC compressor trinary low high pressure switch with wire – Anxin Detail:

This is an air conditioner three-state pressure switch, which includes a high and low pressure switch and a medium voltage switch. The three-state pressure switch is installed on the high-pressure pipeline of the air-conditioning system.

Low-pressure switch: When the air-conditioning system leaks or the refrigerant is low, in order to protect the compressor from damage, the control circuit of the compressor is forcibly cut off to stop the compressor.

Mid-state switch: When the condensing pressure is high, force the condensing fan to rotate at a high speed to reduce the high pressure pressure and increase the cooling effect.

High pressure switch: In order to prevent the system pressure from being too high, causing the system to explode, the compressor is forced to stop working. When the high-pressure pressure of the air conditioner is abnormally high, the high-pressure switch is opened to cut off the control circuit of the compressor, and the air-conditioning system stops working.

1
2

The air conditioner three-state pressure switch has four lines: two are medium voltage switches, used to control the fan heating fan. The other two are low pressure and high pressure together to control the compression operation.

3
4

As shown in the circuit diagram: after the A/C switch inputs the signal to the air conditioner panel, the air conditioner panel will output the signal to the ternary pressure switch (usually a negative signal),The ternary pressure switch detects the pressure inside the pipeline and whether the high and low pressure are normal. If it is normal, the internal switch will be turned on and send the signal to the engine computer board. The computer board controls the compressor relay to pull in and the compressor works.There is also a wire that is normally grounded. When the internal medium voltage of the three-state switch is normal, the switch is closed, and the signal is sent to the engine computer board to control the cooling fan relay to pull in.

DSC_0118
DSC_0049
4-30-9
DSC_0123
5-9-14
5-9-142
5-9-143
5-9-145
5-9-144
5-9-141


Product detail pictures:

Short Lead Time for Water Pressure Switch - AC compressor trinary low high pressure switch with wire – Anxin detail pictures

Short Lead Time for Water Pressure Switch - AC compressor trinary low high pressure switch with wire – Anxin detail pictures

Short Lead Time for Water Pressure Switch - AC compressor trinary low high pressure switch with wire – Anxin detail pictures

Short Lead Time for Water Pressure Switch - AC compressor trinary low high pressure switch with wire – Anxin detail pictures

Short Lead Time for Water Pressure Switch - AC compressor trinary low high pressure switch with wire – Anxin detail pictures

Short Lead Time for Water Pressure Switch - AC compressor trinary low high pressure switch with wire – Anxin detail pictures

Short Lead Time for Water Pressure Switch - AC compressor trinary low high pressure switch with wire – Anxin detail pictures

Short Lead Time for Water Pressure Switch - AC compressor trinary low high pressure switch with wire – Anxin detail pictures


Related Product Guide:

Our company puts emphasis on the management, the introduction of talented personnel, and the construction of staff building, trying hard to improve the quality and liability consciousness of staff members. Our company successfully attained IS9001 Certification and European CE Certification of Short Lead Time for Water Pressure Switch - AC compressor trinary low high pressure switch with wire – Anxin , The product will supply to all over the world, such as: Seattle, Casablanca, Danish, We offer OEM services and replacement parts to meet the varying needs of our customers. We offer competitive price for quality products and we will make certain your shipment is handled quickly by our logistics department. We sincerely hope to have the opportunity to meet with you and see how we can help you further your own business.
  • We are a small company that has just started, but we get the company leader's attention and gave us a lot of help. Hope we can make progress together!
    5 Stars By Emma from Algeria - 2017.10.27 12:12
    It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Karen from Puerto Rico - 2017.11.11 11:41
    Write your message here and send it to us
    WhatsApp Online Chat !