Products

  • AC compressor trinary low high pressure switch with wire

    AC compressor trinary low high pressure switch with wire

    This is an air conditioner three-state pressure switch, which includes a high and low pressure switch and a medium voltage switch. The three-state pressure switch is installed on the high-pressure pipeline of the air-conditioning system.

    Low-pressure switch: When the air-conditioning system leaks or the refrigerant is low, in order to protect the compressor from damage, the control circuit of the compressor is forcibly cut off to stop the compressor.

    Mid-state switch: When the condensing pressure is high, force the condensing fan to rotate at a high speed to reduce the high pressure pressure and increase the cooling effect.

    High pressure switch: In order to prevent the system pressure from being too high, causing the system to explode, the compressor is forced to stop working. When the high-pressure pressure of the air conditioner is abnormally high, the high-pressure switch is opened to cut off the control circuit of the compressor, and the air-conditioning system stops working.

  • Auto Air Conditioning Refrigeration Pressure Switch

    Auto Air Conditioning Refrigeration Pressure Switch

    The pressure switch is installed on the high-pressure side of the air-conditioning system.When the refrigerant pressure is ≤0.196MPa, since the elastic force of the diaphragm, the butterfly spring and the upper spring is greater than the pressure of the refrigerant, the high and low pressure contacts are disconnected (OFF), the compressor stops, and low pressure protection is realized.

    When the refrigerant pressure reaches 0.2MPa or more, this pressure is higher than the spring pressure of the switch, the spring will bend, the high and low pressure contacts are turned on (ON), and the compressor operates normally.

  • air ride bag tank pressure switch sealed for air compressor and train horn

    air ride bag tank pressure switch sealed for air compressor and train horn

    The pressure setting range of this switch is relatively flexible, and it has a wide range of applications. The most common ones are used in various small air pumps, car horns and air compressors.Usually there is a threaded interface, and the switch tail can be welded to the wire. The specification of the wire is according to your requirements, as shown in the figure below

  • On Board Air Conditioning Pressure Switch

    On Board Air Conditioning Pressure Switch

    The main applicable models of this air-conditioning pressure switch are as follows: Dongfeng, peugeot, 307, 206, 207, 308, 408, 508, 3008, 2008, 301, 308S, 4008, 5008, Citroen, Sega, C2, Senna, Picasso, C4L C4 Sega C6 C3-XR Elysee New Elysee Beverly C5 C5 Tianyi Fengshen A9 AX7 AX4 AX3 A60 L60 A30 S30 H30.The above complaints all refer to applicable models, not any product brands.

  • Pressure Switch For Refrigeration System

    Pressure Switch For Refrigeration System

    The pressure switch is mainly used in the refrigeration system, in the pipeline circulation system of high pressure and low pressure, to protect the abnormal high pressure of the system to prevent damage to the compressor.

    After being filled, the refrigerant flows into the aluminum shell (that is, inside the switch) through the small hole under the aluminum shell. The inner cavity uses a rectangular ring and a diaphragm to separate the refrigerant from the electrical part and seal it at the same time.

  • Automobile Air Conditioning Pressure Switch

    Automobile Air Conditioning Pressure Switch

    The automobile air conditioner pressure switch is a part to protect the air conditioner refrigeration, it can adjust the pressure in time.When the refrigerant pressure in the air conditioning system is too high or too low, the pressure switch is turned off, so that the compressor does not work (the pressure switch and other switches control the relay to control the compressor) and protect the system components from damage.Generally divided into two-state pressure switch and three-state pressure switch. The pressure switch is generally connected to the compressor, the condenser electric fan or the water tank fan. It is controlled by the ECU on the car and controls the opening of the fan according to the pressure change in the air conditioner. Turn off, or the air volume, when the pressure is too high, the compressor will stop working to protect the system.

  • 12v /24v Barb Fitting normally open or normally closed pressure switch

    12v /24v Barb Fitting normally open or normally closed pressure switch

    This is a pressure switch with a pagoda-shaped joint, and its joint is in a continuous cone shape.

    So it can be better connected with water pipes and air pipes.

    This pressure switch is mostly used in air compressors, small air pumps, and water pumps, air tank.

    Air pipe or water pipe can be installed at its interface.

  • High And Low Pressure Pressure Switch

    High And Low Pressure Pressure Switch

    This pressure switch can be used in many fields, such as air conditioning refrigeration systems, car horns, ARB air pumps, air compressors, etc.In the refrigeration and air-conditioning system, the general air-conditioning pressure switch is installed in the air-conditioning condensing pipe, mainly to detect the pressure of the refrigerant in the air-conditioning pipe.When the pressure is abnormal, the corresponding protection circuit is activated to prevent damage to the system.Common air-conditioning pressure switches generally include high-pressure switches, low-pressure switches, two state pressure switches and three state pressure switches.

  • Adjustable differential air pressure switch

    Adjustable differential air pressure switch

    Electrical parameters : 5(2.5)A 125/250V

    Pressure setting: 20pa~5000pa

    Applicable pressure: Positive or negative pressure

    Contact resistance: ≤50mΩ

    Maximum breakage pressure: 10kpa

    Operating temperature: -20℃~85℃

    Connection size: Diameter 6mm

    Insulation resistance: 500V-DC-lasted 1min,≥5MΩ

  • Wall-hung boiler gas furnace air pressure switch
  • Miniature 4-20ma/5v Gas And Liquid  Sealed And Water Proof Pressure Transducer

    Miniature 4-20ma/5v Gas And Liquid Sealed And Water Proof Pressure Transducer

    This series ultra-stable pressure sensor adopts stainless steel isolated small structureIt has a wide range and a variety of output signals.The sensor uses solid-state ultra-stable technology, has good stability in a wide temperature range, and is the most cost-effective among similar products.Standard output includes 0~10mV/V (constant voltage and constant current), 0.5V~4.5V (ratio output), 1V~5V (regulated output) and 4~20mA (loop output).High-quality sensors, superb packaging technology and perfect assembly process ensure the high quality and excellent performance of this product.This product has a variety of interface forms and a variety of lead methods, which can meet the needs of customers to the greatest extent, and is especially suitable for use with various equipment.

  • Hvac Refrigerant Coolant Pressure Sensor And Transmitter

    Hvac Refrigerant Coolant Pressure Sensor And Transmitter

    The transmitter adopts the international advanced pressure sensing element and transmitter special integrated circuit, which is a high-quality, highly reliable, and anti-overload pressure transmitter.It adopts special pressure chips for refrigeration, air conditioning, and heat pump systems, which are corrosion-resistant, impact-resistant, and have good strong corrosion resistance to refrigerants, which can meet the vibration and impact requirements of refrigeration units, and have stable and reliable performance.Mainly used in water-cooled screw units, ground source heat pumps, refrigerators, ice machines, etc. Its unique anti-condensation design plays a pressure protection role for the safe and efficient operation of the equipment.