Name
Current/Voltage Pressure Transmitter
Shell material
304 stainless steel
Core category
Ceramic core, diffused silicon oil-filled core (optional)
Pressure type
Gauge pressure type, absolute pressure type or sealed gauge pressure type
Range
-100kpa…0~20kpa…100MPA (optional)
Temperature compensation
-10-70°C
Precision
0.25%FS, 0.5%FS, 1%FS (comprehensive error including non-linear repeatability hysteresis)
Operating temperature
-40-125℃
Safety overload
2 times full sca...
Measuring medium
Various liquids, gases or vapors compatible with 304 and 316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Safety overload
2 times full scale pressure
output signal
4~20mADC (two-wire system), 0~10mADC, 0~20mADC, 0~5VDC, 1~5VDC, 0.5-4.5V, 0~10VDC (three-wire system)
Power supply
8~32VDC
Medium temperature
-20℃~85℃
Operating temperature
-40-125℃
Relative humidity
0%~100%
Rise Time
90% FS can be reached in l...
1. Product name: Pagoda Head Insert Type Water Pump Air Pump Pressure Switch, high quality through CE, ROSH certification
2. Pressure control range::0-10MPA
3. Pressure value: According to customer requirements
4. Interface type: pagoda head interface, can be equipped with air pipe
5. Interface material:Galvanized iron
6. Interface size: 6.35mm diameter
7. Connection mode: insert piece, insert piece can be welded with wire, wire tail can be equipped with connector.
8.Size of inserting piece:...
Scope of application
Pressure measurement in industrial process control system
Measured medium
Various media compatible with 316L
Range (gauge pressure, absolute pressure)
Example :0~10kpa 0~16kpa 0~25kpa 0~40kpa 0~0.06Mpa 0~0.1Mpa 0~0.16Mpa 0~0.25Mpa 0~0.4Mpa 0~0.6Mpa 0~10Mpa 0~16Mpa 0~25Mpa 0~40Mpa 0~40Mpa 0~0.06Mpa 0~100Mpa 0~160Mpa
overload
For measuring range ≤10Mpa, 2 times For measuring range> 10Mpa, 1.5 times
Accuracy (including linearity, hysteresis, re...
Scope of application
Pressure measurement in industrial process control system
Measured medium
Various media compatible with 316L
Range (gauge pressure, absolute pressure)
Example :0~10kpa 0~16kpa 0~25kpa 0~40kpa 0~0.06Mpa 0~0.1Mpa 0~0.16Mpa 0~0.25Mpa 0~0.4Mpa 0~0.6Mpa 0~10Mpa 0~16Mpa 0~25Mpa 0~40Mpa 0~40Mpa 0~0.06Mpa 0~100Mpa 0~160Mpa
overload
For measuring range ≤10Mpa, 2 times For measuring range> 10Mpa, 1.5 times
Accuracy (including linearity, hysteresis, re...
1.Product name: Refrigeration Pressure Switch, Air Compressor Pressure Switch, Steam Pressure Switch, Water Pump Pressure Switch
2. Use medium: refrigerant, gas, liquid, water, oil
3.Electrical parameters: 125V/250V AC 12A
4. Medium temperature: -10~120℃
5. Installation interface; 7/16-20, G1/4, G1/8, M12*1.25, φ6 copper tube, φ2.5mm capillary tube, or customized according to customer requirements
6. Working principle: The switch is normally closed. When the access pressure is greater than th...
The pressure switch is mainly used in the refrigeration system, in the pipeline circulation system of high pressure and low pressure, to protect the abnormal high pressure of the system to prevent damage to the compressor.
After being filled, the refrigerant flows into the aluminum shell (that is, inside the switch) through the small hole under the aluminum shell. The inner cavity uses a rectangular ring and a diaphragm to separate the refrigerant from the electrical part ...