Name
Current/Voltage Pressure Transmitter
Shell material
304 stainless steel
Core category
Ceramic core, diffused silicon oil-filled core (optional)
Pressure type
Gauge pressure type, absolute pressure type or sealed gauge pressure type
Range
-100kpa…0~20kpa…100MPA (optional)
Temperature compensation
-10-70°C
Precision
0.25%FS, 0.5%FS, 1%FS (comprehensive error including non-linear repeatability hysteresis)
Operating temperature
-40-125℃
Safety overload
2 times full sca...
1: Wide pressure control range:You can choose any on and off value (including negative pressure value) for the switch, and we will customize it for you.
2: Applicable medium: liquid, gas, refrigerant
3: Interface method: The interface of this pressure switch is a threaded interface,Commonly used thread specifications are G1/8, NPT1/8, G1/4, NPT1/4, M10*1, etc.The thread can be customized according to your requirements.In addition to this, there can also be small copper pipe interfaces, large...
Switch
SPST (single pole single throw); SPDT (single pole double throw)
Exact point type
Normally closed or normally open
Mechanical life
1 million times
Rated current
DC/AC 5V/12V/24V/36V 1A 120V/250V 3A
Pressure parameters
Yk-023a7 inch Hg / 3 inch Hg vacuum range 0 ~ -0.1mpa; Yk-023n8 inch Hg / 4 inch Hg vacuum range 0 ~ -0.1mpa; Yk-023c7 inches of mercury / 4 inches of mercury use really! O range: 0 ~ 0.1MPa
Wireway
CRCC certified low smoke halogen-free conductor shall comply...
Name
Current/Voltage Pressure Transmitter
Shell material
304 stainless steel
Core category
Ceramic core, diffused silicon oil-filled core (optional)
Pressure type
Gauge pressure type, absolute pressure type or sealed gauge pressure type
Range
-100kpa…0~20kpa…100MPA (optional)
Temperature compensation
-10-70°C
Precision
0.25%FS, 0.5%FS, 1%FS (comprehensive error including non-linear repeatability hysteresis)
Operating temperature
-40-125℃
Safety overload
2 times full sca...
Name
Applicable medium
Air conditioning refrigeration medium, water, gas, oil, etc.
Pressure setting range
-100kpa~10Mpa In this range, the equipment in the factory is carried out according to customer requirements, and cannot be changed after leaving the factory.
Contact form
Normally open, normally closed, single pole double throw
Contact resistance
≤50MΩ
Medium temperature
High temperature resistant products can be customized
Working voltage, current
120/240VAC,...
Product name
Air Pressure Switch, Air Pump Pressure Switch, Air Compressor Pressure Switch
Applicable medium
Air, refrigerant, oil, water
Pressure setting range
0-50Mpa (The pressure parameter can be set according to the needs of your equipment and can be customized)
Thread
Commonly used are G1/4 NPT1/4 G1/8 NPT1/8 or customized according to customer requirements
Withstand voltage
Burst pressure
Operating temperature
-30° C ~ 80° C
Operating Voltage
12V/24V
Workin...
1: Wide pressure control range:You can choose any on and off value (including negative pressure value) for the switch, and we will customize it for you.
2: Applicable medium: liquid, gas, refrigerant
3: Interface method: The interface of this pressure switch is a threaded interface,Commonly used thread specifications are G1/8, NPT1/8, G1/4, NPT1/4, M10*1, etc.The thread can be customized according to your requirements.In addition to this, there can also be small copper pipe interfaces, large...
Measuring medium
various liquid, gas or steam compatible with 304、316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Overload pressure
2 times full scale
output signal
4~20mA (two-wire system), 0-10VDC, 0-5VDC, 1-5VDC (three-wire system)
Supply voltage
8~32VDC
Operating temperature
-40-125℃
Temperature compensation
-10-70°C
Relative humidity
0%~100%
Rise Time
90% FS can be reached in less than 5 milliseconds
Accuracy...
Measuring medium
various liquid, gas or steam compatible with 304、316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Overload pressure
2 times full scale
output signal
4~20mA (two-wire system), 0-10VDC, 0-5VDC, 1-5VDC (three-wire system)
Supply voltage
8~32VDC
Operating temperature
-40-125℃
Temperature compensation
-10-70°C
Relative humidity
0%~100%
Rise Time
90% FS can be reached in less than 5 milliseconds
Accuracy...
1.Product name: Refrigeration Pressure Switch, Air Compressor Pressure Switch, Steam Pressure Switch, Water Pump Pressure Switch
2. Use medium: refrigerant, gas, liquid, water, oil
3.Electrical parameters: 125V/250V AC 12A
4. Medium temperature: -10~120℃
5. Installation interface; 7/16-20, G1/4, G1/8, M12*1.25, φ6 copper tube, φ2.5mm capillary tube, or customized according to customer requirements
6. Working principle: The switch is normally closed. When the access pressure is greater than th...
This is an air conditioner three-state pressure switch, which includes a high and low pressure switch and a medium voltage switch. The three-state pressure switch is installed on the high-pressure pipeline of the air-conditioning system.
Low-pressure switch: When the air-conditioning system leaks or the refrigerant is low, in order to protect the compressor from damage, the control circuit of the compressor is forcibly cut off to stop the compressor.
Mid-state switch: When the condensing pres...