1.Working pressure range: -100kpa~10Mpa, Parameter setting: The start and stop value of the pressure switch can be set according to customer requirements. All parameters are set in the factory , and cannot be adjusted after leaving the factory. If you need to adjust, please select the adjustable pressure switc
2. Bursting pressure: 34.5Mpa
3. Ambient temperature: -30℃~+80℃
4. System medium temperature: -50℃~+120℃, Contact form: normally open, normally closed, single pole double throw, Elec...
Product name
Auto air conditioning refrigeration pressure switch
Thread
1/8, 3/8
Common parameters
HP:3.14Mpa OFF; MP:1.52Mpa ON; LP:0.196Mpa OFF
Applicable medium
R134a, Air conditioning refrigerant
Generally, pressure switches are installed in automobile air-conditioning refrigeration systems.Pressure protection switches include high pressure pressure switch, low pressure pressure switch, high and low pressure combination switch and three-state pressure ...
Product model:MR-2260
Product Name: flow switch
Serial number
Project
Parameter
Remarks
1
Maximum switching current
0.5A(DC)
2
Maximum limit current
1A
3
Maximum contact resistance
100MΩ
4
Maximum load power
10W
50W optional
5
Maximum switching voltage
100V
6
Starting water flow
≥1.5L/min
7
Working flow range
2.0~15L/min
8
Working water pressure
0.1~0.8MPa
9
Maximum beari...
1. It is made of internationally advanced pressure sensor and stainless steel bellows, with stable performance, high pressure precision and superior sealing performance.
2. Extremely high precision, long working life (more than 100,000 times), adopting international advanced welding technology and equipment, superior sealing performance and no leakage.
3. Suitable for different fluid media and corrosive media.
4. Working pressure can be produced according to user requirements, pressure range:...
Name
Applicable medium
Air conditioning refrigeration medium, water, gas, oil, etc.
Pressure setting range
-100kpa~10Mpa In this range, the equipment in the factory is carried out according to customer requirements, and cannot be changed after leaving the factory.
Contact form
Normally open, normally closed, single pole double throw
Contact resistance
≤50MΩ
Medium temperature
High temperature resistant products can be customized
Working voltage, current
120/240VAC,...
Name
Applicable medium
Air conditioning refrigeration medium, water, gas, oil, etc.
Pressure setting range
-100kpa~10Mpa In this range, the equipment in the factory is carried out according to customer requirements, and cannot be changed after leaving the factory.
Contact form
Normally open, normally closed, single pole double throw
Contact resistance
≤50MΩ
Medium temperature
High temperature resistant products can be customized
Working voltage, current
120/240VAC,...
Measuring medium
Various liquids, gases or vapors compatible with 304 and 316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Safety overload
2 times full scale pressure
output signal
4~20mADC (two-wire system), 0~10mADC, 0~20mADC, 0~5VDC, 1~5VDC, 0.5-4.5V, 0~10VDC (three-wire system)
Power supply
8~32VDC
Medium temperature
-20℃~85℃
Operating temperature
-40-125℃
Relative humidity
0%~100%
Rise Time
90% FS can be reached in l...
Conventional
Number value
Remark
Pressure range
-100kpa…0~20kpa…100MPA (optional)
1MPa=10bar1bar≈14.5PSI1PSI=6.8965kPa1kgf/cm2 = 1atmosphere 1
atmosphere ≈ 98kPa
Overload pressure
2 times full scale pressure
Breaking pressure
3 times full scale pressure
Precision
0.25%FS、0.5%FS、1%FS (Higher precision can be customized )
Stability
0.2%FS/year
Operating temperature
-40-125℃
Compensation temperature
-10℃~70℃
Compatible media
All media compatible with 304/316...
1.Product name: Refrigeration Pressure Switch, Air Compressor Pressure Switch, Steam Pressure Switch, Water Pump Pressure Switch
2. Use medium: refrigerant, gas, liquid, water, oil
3.Electrical parameters: 125V/250V AC 12A
4. Medium temperature: -10~120℃
5. Installation interface; 7/16-20, G1/4, G1/8, M12*1.25, φ6 copper tube, φ2.5mm capillary tube, or customized according to customer requirements
6. Working principle: The switch is normally closed. When the access pressure is greater than th...