Measuring medium
Various liquids, gases or vapors compatible with 304 and 316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Safety overload
2 times full scale pressure
output signal
4~20mADC (two-wire system), 0~10mADC, 0~20mADC, 0~5VDC, 1~5VDC, 0.5-4.5V, 0~10VDC (three-wire system)
Power supply
8~32VDC
Medium temperature
-20℃~85℃
Operating temperature
-40-125℃
Relative humidity
0%~100%
Rise Time
90% FS can be reached in l...
Switch
SPST (single pole single throw); SPDT (single pole double throw)
Exact point type
Normally closed or normally open
Mechanical life
1 million times
Rated current
DC/AC 5V/12V/24V/36V 1A 120V/250V 3A
Pressure parameters
Yk-023a7 inch Hg / 3 inch Hg vacuum range 0 ~ -0.1mpa; Yk-023n8 inch Hg / 4 inch Hg vacuum range 0 ~ -0.1mpa; Yk-023c7 inches of mercury / 4 inches of mercury use really! O range: 0 ~ 0.1MPa
Wireway
CRCC certified low smoke halogen-free conductor shall comply...
Measuring medium
Various liquids, gases or vapors compatible with 304 and 316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Safety overload
2 times full scale pressure
output signal
4~20mADC (two-wire system), 0~10mADC, 0~20mADC, 0~5VDC, 1~5VDC, 0.5-4.5V, 0~10VDC (three-wire system)
Power supply
8~32VDC
Medium temperature
-20℃~85℃
Operating temperature
-40-125℃
Relative humidity
0%~100%
Rise Time
90% FS can be reached in l...
Measuring medium
various liquid, gas or steam compatible with 304、316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Overload pressure
2 times full scale
output signal
4~20mA (two-wire system), 0-10VDC, 0-5VDC, 1-5VDC (three-wire system)
Supply voltage
8~32VDC
Operating temperature
-40-125℃
Temperature compensation
-10-70°C
Relative humidity
0%~100%
Rise Time
90% FS can be reached in less than 5 milliseconds
Accuracy...
Switch
SPST (single pole single throw); SPDT (single pole double throw)
Exact point type
Normally closed or normally open
Mechanical life
1 million times
Rated current
DC/AC 5V/12V/24V/36V 1A 120V/250V 3A
Pressure parameters
Yk-023a7 inch Hg / 3 inch Hg vacuum range 0 ~ -0.1mpa; Yk-023n8 inch Hg / 4 inch Hg vacuum range 0 ~ -0.1mpa; Yk-023c7 inches of mercury / 4 inches of mercury use really! O range: 0 ~ 0.1MPa
Wireway
CRCC certified low smoke halogen-free conductor shall comply...
Conventional
Number value
Remark
Pressure range
-100kpa…0~20kpa…100MPA (optional)
1MPa=10bar1bar≈14.5PSI1PSI=6.8965kPa1kgf/cm2 = 1atmosphere 1
atmosphere ≈ 98kPa
Overload pressure
2 times full scale pressure
Breaking pressure
3 times full scale pressure
Precision
0.25%FS、0.5%FS、1%FS (Higher precision can be customized )
Stability
0.2%FS/year
Operating temperature
-40-125℃
Compensation temperature
-10℃~70℃
Compatible media
All media compatible with 304/316...
Name
Current/Voltage Pressure Transmitter
Shell material
304 stainless steel
Core category
Ceramic core, diffused silicon oil-filled core (optional)
Pressure type
Gauge pressure type, absolute pressure type or sealed gauge pressure type
Range
-100kpa…0~20kpa…100MPA (optional)
Temperature compensation
-10-70°C
Precision
0.25%FS, 0.5%FS, 1%FS (comprehensive error including non-linear repeatability hysteresis)
Operating temperature
-40-125℃
Safety overload
2 times full sca...
Product model:MR-2260
Product Name: flow switch
Serial number
Project
Parameter
Remarks
1
Maximum switching current
0.5A(DC)
2
Maximum limit current
1A
3
Maximum contact resistance
100MΩ
4
Maximum load power
10W
50W optional
5
Maximum switching voltage
100V
6
Starting water flow
≥1.5L/min
7
Working flow range
2.0~15L/min
8
Working water pressure
0.1~0.8MPa
9
Maximum beari...
Protection level: IP65
Pressure range:-100kpa~10Mpa
Control form: normally open, normally closed
Electrical connection: wire type and insert type, this switch is wire type, it can also be made into insert type
Interface type: This switch is a quick-cut pagoda-shaped trachea or a threaded joint. The interface thread can be set according to the user’s installation requirements
Working voltage: 6-36VDC, 110-250VDC, high voltage resistance, high current products can be customized according ...