Electrical parameters
5(2.5)A 125/250V
Pressure setting
20pa~5000pa
Applicable pressure
Positive or negative pressure
Contact resistance
≤50mΩ
Maximum breakage pressure
10kpa
Operating temperature
-20℃~85℃
Connection size
Diameter 6mm
Insulation resistance
500V-DC-lasted 1min,≥5MΩ
Control Method
Open and close method
Electric strength
500V—- lasted 1min, no abnormality
Installation method
Recommended for vertical installation
Applicable medium
Non-hazardous gas...
1. It is made of internationally advanced pressure sensor and stainless steel bellows, with stable performance, high pressure precision and superior sealing performance.
2. Extremely high precision, long working life (more than 100,000 times), adopting international advanced welding technology and equipment, superior sealing performance and no leakage.
3. Suitable for different fluid media and corrosive media.
4. Working pressure can be produced according to user requirements, pressure range:...
Product name
Air Pressure Switch, Air Pump Pressure Switch, Air Compressor Pressure Switch
Applicable medium
Air, refrigerant, oil, water
Pressure setting range
0-50Mpa (The pressure parameter can be set according to the needs of your equipment and can be customized)
Thread
Commonly used are G1/4 NPT1/4 G1/8 NPT1/8 or customized according to customer requirements
Withstand voltage
Burst pressure
Operating temperature
-30° C ~ 80° C
Operating Voltage
12V/24V
Workin...
1: A variety of appearances are available
2: Product parameters act according to user requirements
3: Easy to install, plug and play, convenient and quick
4: Responsive, timely on-off
The automobile air-conditioning pressure switch detects the pressure of the air-conditioning pipeline, and then transmits the pressure signal to the air-conditioning control system to protect the air-conditioning compressor and the pipeline! The air conditioner can work normally only whe...
The pressure switch is mainly used in the refrigeration system, in the pipeline circulation system of high pressure and low pressure, to protect the abnormal high pressure of the system to prevent damage to the compressor.
After being filled, the refrigerant flows into the aluminum shell (that is, inside the switch) through the small hole under the aluminum shell. The inner cavity uses a rectangular ring and a diaphragm to separate the refrigerant from the electrical part ...
Produce name
Hvac high/low on off pressure switch for air conditioner compressor and heat pump
Applicable medium
Liquid, gas, water, oil, steam
Pressure setting range
The pressure setting is according to customer requirements, both positive and negative pressure can be achieved
Switch form
Normally open, normally closed
Working type
Manual reset, automatic reset optional
Medium temperature
High temperature resistant products can be customized
Working voltage, current
120/2...
Scope of application
Pressure measurement in industrial process control system
Measured medium
Various media compatible with 316L
Range (gauge pressure, absolute pressure)
Example :0~10kpa 0~16kpa 0~25kpa 0~40kpa 0~0.06Mpa 0~0.1Mpa 0~0.16Mpa 0~0.25Mpa 0~0.4Mpa 0~0.6Mpa 0~10Mpa 0~16Mpa 0~25Mpa 0~40Mpa 0~40Mpa 0~0.06Mpa 0~100Mpa 0~160Mpa
overload
For measuring range ≤10Mpa, 2 times For measuring range> 10Mpa, 1.5 times
Accuracy (including linearity, hysteresis, re...
Switch
SPST (single pole single throw); SPDT (single pole double throw)
Exact point type
Normally closed or normally open
Mechanical life
1 million times
Rated current
DC/AC 5V/12V/24V/36V 1A 120V/250V 3A
Pressure parameters
Yk-023a7 inch Hg / 3 inch Hg vacuum range 0 ~ -0.1mpa; Yk-023n8 inch Hg / 4 inch Hg vacuum range 0 ~ -0.1mpa; Yk-023c7 inches of mercury / 4 inches of mercury use really! O range: 0 ~ 0.1MPa
Wireway
CRCC certified low smoke halogen-free conductor shall comply...
Conventional
Number value
Remark
Pressure range
-100kpa…0~20kpa…100MPA (optional)
1MPa=10bar1bar≈14.5PSI1PSI=6.8965kPa1kgf/cm2 = 1atmosphere 1
atmosphere ≈ 98kPa
Overload pressure
2 times full scale pressure
Breaking pressure
3 times full scale pressure
Precision
0.25%FS、0.5%FS、1%FS (Higher precision can be customized )
Stability
0.2%FS/year
Operating temperature
-40-125℃
Compensation temperature
-10℃~70℃
Compatible media
All media compatible with 304/316...
Scope of application
Pressure measurement in industrial process control system
Measured medium
Various media compatible with 316L
Range (gauge pressure, absolute pressure)
Example :0~10kpa 0~16kpa 0~25kpa 0~40kpa 0~0.06Mpa 0~0.1Mpa 0~0.16Mpa 0~0.25Mpa 0~0.4Mpa 0~0.6Mpa 0~10Mpa 0~16Mpa 0~25Mpa 0~40Mpa 0~40Mpa 0~0.06Mpa 0~100Mpa 0~160Mpa
overload
For measuring range ≤10Mpa, 2 times For measuring range> 10Mpa, 1.5 times
Accuracy (including linearity, hysteresis, re...