Produce name
Hvac high/low on off pressure switch for air conditioner compressor and heat pump
Applicable medium
Liquid, gas, water, oil, steam
Pressure setting range
The pressure setting is according to customer requirements, both positive and negative pressure can be achieved
Switch form
Normally open, normally closed
Working type
Manual reset, automatic reset optional
Medium temperature
High temperature resistant products can be customized
Working voltage, current
120/2...
1: Wide pressure control range:You can choose any on and off value (including negative pressure value) for the switch, and we will customize it for you.
2: Applicable medium: liquid, gas, refrigerant
3: Interface method: The interface of this pressure switch is a threaded interface,Commonly used thread specifications are G1/8, NPT1/8, G1/4, NPT1/4, M10*1, etc.The thread can be customized according to your requirements.In addition to this, there can also be small copper pipe interfaces, large...
Measuring medium
various liquid, gas or steam compatible with 304、316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Overload pressure
2 times full scale
output signal
4~20mA (two-wire system), 0-10VDC, 0-5VDC, 1-5VDC (three-wire system)
Supply voltage
8~32VDC
Operating temperature
-40-125℃
Temperature compensation
-10-70°C
Relative humidity
0%~100%
Rise Time
90% FS can be reached in less than 5 milliseconds
Accuracy...
Scope of application
Pressure measurement in industrial process control system
Measured medium
Various media compatible with 316L
Range (gauge pressure, absolute pressure)
Example :0~10kpa 0~16kpa 0~25kpa 0~40kpa 0~0.06Mpa 0~0.1Mpa 0~0.16Mpa 0~0.25Mpa 0~0.4Mpa 0~0.6Mpa 0~10Mpa 0~16Mpa 0~25Mpa 0~40Mpa 0~40Mpa 0~0.06Mpa 0~100Mpa 0~160Mpa
overload
For measuring range ≤10Mpa, 2 times For measuring range> 10Mpa, 1.5 times
Accuracy (including linearity, hysteresis, re...
Name
Current/Voltage Pressure Transmitter
Shell material
304 stainless steel
Core category
Ceramic core, diffused silicon oil-filled core (optional)
Pressure type
Gauge pressure type, absolute pressure type or sealed gauge pressure type
Range
-100kpa…0~20kpa…100MPA (optional)
Temperature compensation
-10-70°C
Precision
0.25%FS, 0.5%FS, 1%FS (comprehensive error including non-linear repeatability hysteresis)
Operating temperature
-40-125℃
Safety overload
2 times full sca...
1. Product name: China factory 12v /24v Barb Fitting normally open or normally closed pressure switch could be used for dewalt porter cable air compressor rated 105/135/90/120/150/180/160/200psi and other on off values .high quality through CE, ROSH certification.
2. Pressure control range: 0-10MPA 1MPA=145PSI=10bar.
3. Pressure value: 105-135psi , 90-120psi, 120-150psi, 160-200psi and so on. According to customer requirements.
4. Interface type: Barb connector, can be equipped with air pipe....
1.Electrical parameters: 0.2A 24V DC T150; 0.5A 1A 2.5A 250VAC
2.Operating temperature: -40℃~ 120℃(No frost )
3.Connection size: The normal size is 1/8 or 1/4. Can be customized according to customer requirements
4.lifetime: 1 million times
5.Electrical life : 0.2A 24V DC 1 million times; 0.5A 12V DC 500,000 times; 1A 125V/250VAC 300,000 times
Pressure setting range psi
Pressure division psi
Pressure division kpa
Setting error psi
0.3~1psi
1~7kpa
±0.2psi
1.0~5psi
7~35kpa
±0....
Scope of application
Pressure measurement in industrial process control system
Measured medium
Various media compatible with 316L
Range (gauge pressure, absolute pressure)
Example :0~10kpa 0~16kpa 0~25kpa 0~40kpa 0~0.06Mpa 0~0.1Mpa 0~0.16Mpa 0~0.25Mpa 0~0.4Mpa 0~0.6Mpa 0~10Mpa 0~16Mpa 0~25Mpa 0~40Mpa 0~40Mpa 0~0.06Mpa 0~100Mpa 0~160Mpa
overload
For measuring range ≤10Mpa, 2 times For measuring range> 10Mpa, 1.5 times
Accuracy (including linearity, hysteresis, re...
Conventional
Number value
Remark
Pressure range
-100kpa…0~20kpa…100MPA (optional)
1MPa=10bar1bar≈14.5PSI1PSI=6.8965kPa1kgf/cm2 = 1atmosphere 1
atmosphere ≈ 98kPa
Overload pressure
2 times full scale pressure
Breaking pressure
3 times full scale pressure
Precision
0.25%FS、0.5%FS、1%FS (Higher precision can be customized )
Stability
0.2%FS/year
Operating temperature
-40-125℃
Compensation temperature
-10℃~70℃
Compatible media
All media compatible with 304/316...
1.Product name: Refrigeration Pressure Switch, Air Compressor Pressure Switch, Steam Pressure Switch, Water Pump Pressure Switch
2. Use medium: refrigerant, gas, liquid, water, oil
3.Electrical parameters: 125V/250V AC 12A
4. Medium temperature: -10~120℃
5. Installation interface; 7/16-20, G1/4, G1/8, M12*1.25, φ6 copper tube, φ2.5mm capillary tube, or customized according to customer requirements
6. Working principle: The switch is normally closed. When the access pressure is greater than th...
1: A variety of appearances are available
2: Product parameters act according to user requirements
3: Easy to install, plug and play, convenient and quick
4: Responsive, timely on-off
The automobile air-conditioning pressure switch detects the pressure of the air-conditioning pipeline, and then transmits the pressure signal to the air-conditioning control system to protect the air-conditioning compressor and the pipeline! The air conditioner can work normally only whe...