This is an air conditioner three-state pressure switch, which includes a high and low pressure switch and a medium voltage switch. The three-state pressure switch is installed on the high-pressure pipeline of the air-conditioning system.
Low-pressure switch: When the air-conditioning system leaks or the refrigerant is low, in order to protect the compressor from damage, the control circuit of the compressor is forcibly cut off to stop the compressor.
Mid-state switch: When the condensing pres...
Ceramic pressure sensor module
Name: Voltage type ceramic pressure module
Supply voltage:5/5~16/5~36VDC
range:0~1…1.6…2…3…5…10…20…30MPA
output signal:0.5~4.5V
Response time:<2MS
Measuring medium
Compatible with ceramic water, gas or liquid
long term stability
≤±0.5%FS/year
Operating temperature
-40~125℃
Storage temperature
-40~130℃
Zero temperature coefficient
Typical: ±0.03%FS/℃; Maximum: ±0.05%FS/℃
Sensitivity temperature coeffic...
Conventional
Number value
Remark
Pressure range
-100kpa…0~20kpa…100MPA (optional)
1MPa=10bar1bar≈14.5PSI1PSI=6.8965kPa1kgf/cm2 = 1atmosphere 1atmosphere ≈ 98kPa
Overload pressure
2 times full scale pressure
Breaking pressure
3 times full scale pressure
Precision
0.25%FS、0.5%FS、1%FS (Higher precision can be customized )
Stability
0.2%FS/year
Operating temperature
-40-125℃
Compensation temperature
-10℃~70℃
Compatible media
All media compatible with 304/316 st...
Measuring medium
Various liquids, gases or vapors compatible with 304 and 316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Safety overload
2 times full scale pressure
output signal
4~20mADC (two-wire system), 0~10mADC, 0~20mADC, 0~5VDC, 1~5VDC, 0.5-4.5V, 0~10VDC (three-wire system)
Power supply
8~32VDC
Medium temperature
-20℃~85℃
Operating temperature
-40-125℃
Relative humidity
0%~100%
Rise Time
90% FS can be reached in l...
Switch
SPST (single pole single throw); SPDT (single pole double throw)
Exact point type
Normally closed or normally open
Mechanical life
1 million times
Rated current
DC/AC 5V/12V/24V/36V 1A 120V/250V 3A
Pressure parameters
Yk-023a7 inch Hg / 3 inch Hg vacuum range 0 ~ -0.1mpa; Yk-023n8 inch Hg / 4 inch Hg vacuum range 0 ~ -0.1mpa; Yk-023c7 inches of mercury / 4 inches of mercury use really! O range: 0 ~ 0.1MPa
Wireway
CRCC certified low smoke halogen-free conductor shall comply...
1. Manual reset
2. The appearance is small and exquisite, a variety of wiring and interface types are available for users to choose at will.
3. Single-pole single-throw, single-pole double-throw normally open and normally closed contact types are available for users to choose at will.
3. Extremely high precision, long working life (more than 100,000 times), adopting international advanced welding technology and equipment, superior sealing performance and no leakage.
4. Working pressure can be...
1.Electrical parameters: 0.2A 24V DC T150; 0.5A 1A 2.5A 250VAC
2.Operating temperature: -40℃~ 120℃(No frost )
3.Connection size: The normal size is 1/8 or 1/4. Can be customized according to customer requirements
4.lifetime: 1 million times
5.Electrical life : 0.2A 24V DC 1 million times; 0.5A 12V DC 500,000 times; 1A 125V/250VAC 300,000 times
Pressure setting range psi
Pressure division psi
Pressure division kpa
Setting error psi
0.3~1psi
1~7kpa
±0.2psi
1.0~5psi
7~35kpa
±0....
Name
Current/Voltage Pressure Transmitter
Shell material
304 stainless steel
Core category
Ceramic core, diffused silicon oil-filled core (optional)
Pressure type
Gauge pressure type, absolute pressure type or sealed gauge pressure type
Range
-100kpa…0~20kpa…100MPA (optional)
Temperature compensation
-10-70°C
Precision
0.25%FS, 0.5%FS, 1%FS (comprehensive error including non-linear repeatability hysteresis)
Operating temperature
-40-125℃
Safety overload
2 times full sca...
Ceramic pressure sensor module
Name: Voltage type ceramic pressure module
Supply voltage:5/5~16/5~36VDC
range:0~1…1.6…2…3…5…10…20…30MPA
output signal:0.5~4.5V
Response time:<2MS
Measuring medium
Compatible with ceramic water, gas or liquid
long term stability
≤±0.5%FS/year
Operating temperature
-40~125℃
Storage temperature
-40~130℃
Zero temperature coefficient
Typical: ±0.03%FS/℃; Maximum: ±0.05%FS/℃
Sensitivity temperature coeffic...
Product model:MR-2260
Product Name: flow switch
Serial number
Project
Parameter
Remarks
1
Maximum switching current
0.5A(DC)
2
Maximum limit current
1A
3
Maximum contact resistance
100MΩ
4
Maximum load power
10W
50W optional
5
Maximum switching voltage
100V
6
Starting water flow
≥1.5L/min
7
Working flow range
2.0~15L/min
8
Working water pressure
0.1~0.8MPa
9
Maximum bearing wate...
1. Product name: China factory 12v /24v Barb Fitting normally open or normally closed pressure switch could be used for dewalt porter cable air compressor rated 105/135/90/120/150/180/160/200psi and other on off values .high quality through CE, ROSH certification.
2. Pressure control range: 0-10MPA 1MPA=145PSI=10bar.
3. Pressure value: 105-135psi , 90-120psi, 120-150psi, 160-200psi and so on. According to customer requirements.
4. Interface type: Barb connector, can be equipped with air pipe....
Ceramic pressure sensor module
Name: Voltage type ceramic pressure module
Supply voltage:5/5~16/5~36VDC
range:0~1…1.6…2…3…5…10…20…30MPA
output signal:0.5~4.5V
Response time:<2MS
Measuring medium
Compatible with ceramic water, gas or liquid
long term stability
≤±0.5%FS/year
Operating temperature
-40~125℃
Storage temperature
-40~130℃
Zero temperature coefficient
Typical: ±0.03%FS/℃; Maximum: ±0.05%FS/℃
Sensitivity temperature coeffic...