Measuring medium
Various liquids, gases or vapors compatible with 304 and 316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Safety overload
2 times full scale pressure
output signal
4~20mADC (two-wire system), 0~10mADC, 0~20mADC, 0~5VDC, 1~5VDC, 0.5-4.5V, 0~10VDC (three-wire system)
Power supply
8~32VDC
Medium temperature
-20℃~85℃
Operating temperature
-40-125℃
Relative humidity
0%~100%
Rise Time
90% FS can be reached in l...
NAME
High And Low Pressure Pressure Switch/Two state pressure switch/Air conditioning refrigeration pressure switch/R134a pressure switch
MODEL
HFC-134a
PRESSURE VALUE
High pressure:3.14Mpa/2.65Mpa、Low pressure:0.196Mpa (This value can be customized according to your requirements )
Thread size
1/8 、 3/8 (Thread size can be customized according to your requirements )
Inserting type
Two inserting pieces( can be welded with the wire and has a sealing s...
Measuring medium
Various liquids, gases or vapors compatible with 304 and 316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Safety overload
2 times full scale pressure
output signal
4~20mADC (two-wire system), 0~10mADC, 0~20mADC, 0~5VDC, 1~5VDC, 0.5-4.5V, 0~10VDC (three-wire system)
Power supply
8~32VDC
Medium temperature
-20℃~85℃
Operating temperature
-40-125℃
Relative humidity
0%~100%
Rise Time
90% FS can be reached in l...
Scope of application
Pressure measurement in industrial process control system
Measured medium
Various media compatible with 316L
Range (gauge pressure, absolute pressure)
Example :0~10kpa 0~16kpa 0~25kpa 0~40kpa 0~0.06Mpa 0~0.1Mpa 0~0.16Mpa 0~0.25Mpa 0~0.4Mpa 0~0.6Mpa 0~10Mpa 0~16Mpa 0~25Mpa 0~40Mpa 0~40Mpa 0~0.06Mpa 0~100Mpa 0~160Mpa
overload
For measuring range ≤10Mpa, 2 times For measuring range> 10Mpa, 1.5 times
Accuracy (including linearity, hysteresis, re...
1. It is made of internationally advanced pressure sensor and stainless steel bellows, with stable performance, high pressure precision and superior sealing performance.
2. Extremely high precision, long working life (more than 100,000 times), adopting international advanced welding technology and equipment, superior sealing performance and no leakage.
3. Suitable for different fluid media and corrosive media.
4. Working pressure can be produced according to user requirements, pressure range:...
Protection level: IP65
Pressure range:-100kpa~10Mpa
Control form: normally open, normally closed
Electrical connection: wire type and insert type, this switch is wire type, it can also be made into insert type
Interface type: This switch is a quick-cut pagoda-shaped trachea or a threaded joint. The interface thread can be set according to the user’s installation requirements
Working voltage: 6-36VDC, 110-250VDC, high voltage resistance, high current products can be customized according ...
1.Electrical parameters: 0.2A 24V DC T150; 0.5A 1A 2.5A 250VAC
2.Operating temperature: -40℃~ 120℃(No frost )
3.Connection size: The normal size is 1/8 or 1/4. Can be customized according to customer requirements
4.lifetime: 1 million times
5.Electrical life : 0.2A 24V DC 1 million times; 0.5A 12V DC 500,000 times; 1A 125V/250VAC 300,000 times
Pressure setting range psi
Pressure division psi
Pressure division kpa
Setting error psi
0.3~1psi
1~7kpa
±0.2psi
1.0~5psi
7~35kpa
±0....
Name
Applicable medium
Air conditioning refrigeration medium, water, gas, oil, etc.
Pressure setting range
-100kpa~10Mpa In this range, the equipment in the factory is carried out according to customer requirements, and cannot be changed after leaving the factory.
Contact form
Normally open, normally closed, single pole double throw
Contact resistance
≤50MΩ
Medium temperature
High temperature resistant products can be customized
Working voltage, current
120/240VAC,...
Scope of application
Pressure measurement in industrial process control system
Measured medium
Various media compatible with 316L
Range (gauge pressure, absolute pressure)
Example :0~10kpa 0~16kpa 0~25kpa 0~40kpa 0~0.06Mpa 0~0.1Mpa 0~0.16Mpa 0~0.25Mpa 0~0.4Mpa 0~0.6Mpa 0~10Mpa 0~16Mpa 0~25Mpa 0~40Mpa 0~40Mpa 0~0.06Mpa 0~100Mpa 0~160Mpa
overload
For measuring range ≤10Mpa, 2 times For measuring range> 10Mpa, 1.5 times
Accuracy (including linearity, hysteresis, re...
Electrical parameters
5(2.5)A 125/250V
Pressure setting
20pa~5000pa
Applicable pressure
Positive or negative pressure
Contact resistance
≤50mΩ
Maximum breakage pressure
10kpa
Operating temperature
-20℃~85℃
Connection size
Diameter 6mm
Insulation resistance
500V-DC-lasted 1min,≥5MΩ
Control Method
Open and close method
Electric strength
500V—- lasted 1min, no abnormality
Installation method
Recommended for vertical installation
Applicable medium
Non-hazardous gas...
Product model:MR-2260
Product Name: flow switch
Serial number
Project
Parameter
Remarks
1
Maximum switching current
0.5A(DC)
2
Maximum limit current
1A
3
Maximum contact resistance
100MΩ
4
Maximum load power
10W
50W optional
5
Maximum switching voltage
100V
6
Starting water flow
≥1.5L/min
7
Working flow range
2.0~15L/min
8
Working water pressure
0.1~0.8MPa
9
Maximum beari...
Measuring medium
Various liquids, gases or vapors compatible with 304 and 316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Safety overload
2 times full scale pressure
output signal
4~20mADC (two-wire system), 0~10mADC, 0~20mADC, 0~5VDC, 1~5VDC, 0.5-4.5V, 0~10VDC (three-wire system)
Power supply
8~32VDC
Medium temperature
-20℃~85℃
Operating temperature
-40-125℃
Relative humidity
0%~100%
Rise Time
90% FS can be reached in l...