Scope of application
Pressure measurement in industrial process control system
Measured medium
Various media compatible with 316L
Range (gauge pressure, absolute pressure)
Example :0~10kpa 0~16kpa 0~25kpa 0~40kpa 0~0.06Mpa 0~0.1Mpa 0~0.16Mpa 0~0.25Mpa 0~0.4Mpa 0~0.6Mpa 0~10Mpa 0~16Mpa 0~25Mpa 0~40Mpa 0~40Mpa 0~0.06Mpa 0~100Mpa 0~160Mpa
overload
For measuring range ≤10Mpa, 2 times For measuring range> 10Mpa, 1.5 times
Accuracy (including linearity, hysteresis, re...
1. Product name: China factory 12v /24v Barb Fitting normally open or normally closed pressure switch could be used for dewalt porter cable air compressor rated 105/135/90/120/150/180/160/200psi and other on off values .high quality through CE, ROSH certification.
2. Pressure control range: 0-10MPA 1MPA=145PSI=10bar.
3. Pressure value: 105-135psi , 90-120psi, 120-150psi, 160-200psi and so on. According to customer requirements.
4. Interface type: Barb connector, can be equipped with air pipe....
Product name
12/24/36v air ride bag tank pressure switch sealed for air compressor and train horn
Applicable medium
Air, refrigerant, oil, water
Pressure setting range
0-50Mpa (The pressure parameter can be set according to the needs of your equipment and can be customized)
Thread
Commonly used are G1/4 NPT1/4 G1/8 NPT1/8 or customized according to customer requirements
Operating temperature
-30° C ~ 80° C
Operating Voltage
12V/24V
Working current
5A
Terminals
6.35 x ...
1. It is made of internationally advanced pressure sensor and stainless steel bellows, with stable performance, high pressure precision and superior sealing performance.
2. Extremely high precision, long working life (more than 100,000 times), adopting international advanced welding technology and equipment, superior sealing performance and no leakage.
3. Suitable for different fluid media and corrosive media.
4. Working pressure can be produced according to user requirements, pressure range:...
Product name
4 pin high low A/C trinary pressure switch for air conditioner Refrigerant
Thread
1/8, 3/8
Common parameters
HP:3.14Mpa OFF; MP:1.52Mpa ON; LP:0.196Mpa OFF
Applicable medium
R134a, Air conditioning refrigerant
Generally, pressure switches are installed in automobile air-conditioning refrigeration systems.Pressure protection switches include high pressure pressure switch, low pressure pressure switch, high and low pressure combination switch a...
The automobile air conditioner pressure switch is a part to protect the air conditioner refrigeration, it can adjust the pressure in time.When the refrigerant pressure in the air conditioning system is too high or too low, the pressure switch is turned off, so that the compressor does not work (the pressure switch and other switches control the relay to control the compressor) and protect the system components from damage.Generally divided into two-state pressure switch and three-state pressu...
The pressure switch is mainly used in the refrigeration system, in the pipeline circulation system of high pressure and low pressure, to protect the abnormal high pressure of the system to prevent damage to the compressor.
After being filled, the refrigerant flows into the aluminum shell (that is, inside the switch) through the small hole under the aluminum shell. The inner cavity uses a rectangular ring and a diaphragm to separate the refrigerant from the electrical part ...
Electrical parameters
5(2.5)A 125/250V
Pressure setting
20pa~5000pa
Applicable pressure
Positive or negative pressure
Contact resistance
≤50mΩ
Maximum breakage pressure
10kpa
Operating temperature
-20℃~85℃
Connection size
Diameter 6mm
Insulation resistance
500V-DC-lasted 1min,≥5MΩ
Control Method
Open and close method
Electric strength
500V—- lasted 1min, no abnormality
Installation method
Recommended for vertical installation
Applicable medium
Non-hazardous gas...
Measuring medium
various liquid, gas or steam compatible with 304、316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Overload pressure
2 times full scale
output signal
4~20mA (two-wire system), 0-10VDC, 0-5VDC, 1-5VDC (three-wire system)
Supply voltage
8~32VDC
Operating temperature
-40-125℃
Temperature compensation
-10-70°C
Relative humidity
0%~100%
Rise Time
90% FS can be reached in less than 5 milliseconds
Accuracy...