Name
high and low pressure switch/ac binary pressure switch/airconditioning refrigeration pressure switch/r134a/410a/r22 pressure switch
Pressure Value
high pressure: 3.14mpa/2.65mpa, low pressure: 0.196mpa (this value can be customized according to your requirements )
Thread Size
1/8, 3/8, 7/16(thread size can be customized according to your requirements )
Inserting Type
two inserting pieces( can be welded with the wire and has a sealing sleeve ) ...
Switch
SPST (single pole single throw); SPDT (single pole double throw)
Exact point type
Normally closed or normally open
Mechanical life
1 million times
Rated current
DC/AC 5V/12V/24V/36V 1A 120V/250V 3A
Pressure parameters
Yk-023a7 inch Hg / 3 inch Hg vacuum range 0 ~ -0.1mpa; Yk-023n8 inch Hg / 4 inch Hg vacuum range 0 ~ -0.1mpa; Yk-023c7 inches of mercury / 4 inches of mercury use really! O range: 0 ~ 0.1MPa
Wireway
CRCC certified low smoke halogen-free conductor shall comply...
Measuring medium
Various liquids, gases or vapors compatible with 304 and 316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Safety overload
2 times full scale pressure
output signal
4~20mADC (two-wire system), 0~10mADC, 0~20mADC, 0~5VDC, 1~5VDC, 0.5-4.5V, 0~10VDC (three-wire system)
Power supply
8~32VDC
Medium temperature
-20℃~85℃
Operating temperature
-40-125℃
Relative humidity
0%~100%
Rise Time
90% FS can be reached in l...
Setting range of pressure value:-100kpa~10Mpa
Contact form: normally closed (H) normally open (L)
Contact capacity: AC250V/3A DC 3~48V, 3A
Contact resistance: ≤50mΩ.
Insulation resistance: ≥100MΩ between the terminal and the shell under DC500V.
Dielectric strength: AC1500V lasts 1min without breakdown
Compressive strength: 4.5Mpa10min without bursting.
Air tightness: 4.5Mpa1min without leakage.
Service life: 100,000 times.
Adaptation temperature: ambient temperature -30℃~+80℃, medium temper...
Produce name
Hvac high/low on off pressure switch for air conditioner compressor and heat pump
Applicable medium
Liquid, gas, water, oil, steam
Pressure setting range
The pressure setting is according to customer requirements, both positive and negative pressure can be achieved
Switch form
Normally open, normally closed
Working type
Manual reset, automatic reset optional
Medium temperature
High temperature resistant products can be customized
Working voltage, current
120/2...
1.Electrical parameters: 0.2A 24V DC T150; 0.5A 1A 2.5A 250VAC
2.Operating temperature: -40℃~ 120℃(No frost )
3.Connection size: The normal size is 1/8 or 1/4. Can be customized according to customer requirements
4.lifetime: 1 million times
5.Electrical life : 0.2A 24V DC 1 million times; 0.5A 12V DC 500,000 times; 1A 125V/250VAC 300,000 times
Pressure setting range psi
Pressure division psi
Pressure division kpa
Setting error psi
0.3~1psi
1~7kpa
±0.2psi
1.0~5psi
7~35kpa
±0....
Setting range of pressure value:-100kpa~10Mpa
Contact form: normally closed (H) normally open (L)
Contact capacity: AC250V/3A DC 3~48V, 3A
Contact resistance: ≤50mΩ.
Insulation resistance: ≥100MΩ between the terminal and the shell under DC500V.
Dielectric strength: AC1500V lasts 1min without breakdown
Compressive strength: 4.5Mpa10min without bursting.
Air tightness: 4.5Mpa1min without leakage.
Service life: 100,000 times.
Adaptation temperature: ambient temperature -30℃~+80℃, medium temper...
Name
Current/Voltage Pressure Transmitter
Shell material
304 stainless steel
Core category
Ceramic core, diffused silicon oil-filled core (optional)
Pressure type
Gauge pressure type, absolute pressure type or sealed gauge pressure type
Range
-100kpa…0~20kpa…100MPA (optional)
Temperature compensation
-10-70°C
Precision
0.25%FS, 0.5%FS, 1%FS (comprehensive error including non-linear repeatability hysteresis)
Operating temperature
-40-125℃
Safety overload
2 times full sca...
Measuring medium
Various liquids, gases or vapors compatible with 304 and 316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Safety overload
2 times full scale pressure
output signal
4~20mADC (two-wire system), 0~10mADC, 0~20mADC, 0~5VDC, 1~5VDC, 0.5-4.5V, 0~10VDC (three-wire system)
Power supply
8~32VDC
Medium temperature
-20℃~85℃
Operating temperature
-40-125℃
Relative humidity
0%~100%
Rise Time
90% FS can be reached in l...
Measuring medium
Various liquids, gases or vapors compatible with 304 and 316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Safety overload
2 times full scale pressure
output signal
4~20mADC (two-wire system), 0~10mADC, 0~20mADC, 0~5VDC, 1~5VDC, 0.5-4.5V, 0~10VDC (three-wire system)
Power supply
8~32VDC
Medium temperature
-20℃~85℃
Operating temperature
-40-125℃
Relative humidity
0%~100%
Rise Time
90% FS can be reached in l...