Name
high and low pressure switch/ac binary pressure switch/airconditioning refrigeration pressure switch/r134a/410a/r22 pressure switch
Pressure Value
high pressure: 3.14mpa/2.65mpa, low pressure: 0.196mpa (this value can be customized according to your requirements )
Thread Size
1/8, 3/8, 7/16(thread size can be customized according to your requirements )
Inserting Type
two inserting pieces( can be welded with the wire and has a sealing sleeve ) ...
Scope of application
Pressure measurement in industrial process control system
Measured medium
Various media compatible with 316L
Range (gauge pressure, absolute pressure)
Example :0~10kpa 0~16kpa 0~25kpa 0~40kpa 0~0.06Mpa 0~0.1Mpa 0~0.16Mpa 0~0.25Mpa 0~0.4Mpa 0~0.6Mpa 0~10Mpa 0~16Mpa 0~25Mpa 0~40Mpa 0~40Mpa 0~0.06Mpa 0~100Mpa 0~160Mpa
overload
For measuring range ≤10Mpa, 2 times For measuring range> 10Mpa, 1.5 times
Accuracy (including linearity, hysteresis, re...
Name
Current/Voltage Pressure Transmitter
Shell material
304 stainless steel
Core category
Ceramic core, diffused silicon oil-filled core (optional)
Pressure type
Gauge pressure type, absolute pressure type or sealed gauge pressure type
Range
-100kpa…0~20kpa…100MPA (optional)
Temperature compensation
-10-70°C
Precision
0.25%FS, 0.5%FS, 1%FS (comprehensive error including non-linear repeatability hysteresis)
Operating temperature
-40-125℃
Safety overload
2 times full sca...
1: A variety of appearances are available
2: Product parameters act according to user requirements
3: Easy to install, plug and play, convenient and quick
4: Responsive, timely on-off
The automobile air-conditioning pressure switch detects the pressure of the air-conditioning pipeline, and then transmits the pressure signal to the air-conditioning control system to protect the air-conditioning compressor and the pipeline! The air conditioner can work normally only whe...
Conventional
Number value
Remark
Pressure range
-100kpa…0~20kpa…100MPA (optional)
1MPa=10bar1bar≈14.5PSI1PSI=6.8965kPa1kgf/cm2 = 1atmosphere 1
atmosphere ≈ 98kPa
Overload pressure
2 times full scale pressure
Breaking pressure
3 times full scale pressure
Precision
0.25%FS、0.5%FS、1%FS (Higher precision can be customized )
Stability
0.2%FS/year
Operating temperature
-40-125℃
Compensation temperature
-10℃~70℃
Compatible media
All media compatible with 304/316...
Name
China air condition compressor and heat pump high low pressure switch
Applicable medium
Air conditioning refrigeration medium, water, gas, oil, etc.
Pressure setting range
-100kpa~10Mpa In this range, the equipment in the factory is carried out according to customer requirements, and cannot be changed after leaving the factory.
Contact form
Normally open, normally closed, single pole double throw
Contact resistance
≤50MΩ
Medium temperature
High temperature resistant product...
Product name
4 pin high low A/C trinary pressure switch for air conditioner Refrigerant
Thread
1/8, 3/8
Common parameters
HP:3.14Mpa OFF; MP:1.52Mpa ON; LP:0.196Mpa OFF
Applicable medium
R134a, Air conditioning refrigerant
Generally, pressure switches are installed in automobile air-conditioning refrigeration systems.Pressure protection switches include high pressure pressure switch, low pressure pressure switch, high and low pressure combination switch a...
Scope of application
Pressure measurement in industrial process control system
Measured medium
Various media compatible with 316L
Range (gauge pressure, absolute pressure)
Example :0~10kpa 0~16kpa 0~25kpa 0~40kpa 0~0.06Mpa 0~0.1Mpa 0~0.16Mpa 0~0.25Mpa 0~0.4Mpa 0~0.6Mpa 0~10Mpa 0~16Mpa 0~25Mpa 0~40Mpa 0~40Mpa 0~0.06Mpa 0~100Mpa 0~160Mpa
overload
For measuring range ≤10Mpa, 2 times For measuring range> 10Mpa, 1.5 times
Accuracy (including linearity, hysteresis, re...
1. Product name: China factory 12v /24v Barb Fitting normally open or normally closed pressure switch could be used for dewalt porter cable air compressor rated 105/135/90/120/150/180/160/200psi and other on off values .high quality through CE, ROSH certification.
2. Pressure control range: 0-10MPA 1MPA=145PSI=10bar.
3. Pressure value: 105-135psi , 90-120psi, 120-150psi, 160-200psi and so on. According to customer requirements.
4. Interface type: Barb connector, can be equipped with air pipe....
Electrical parameters
5(2.5)A 125/250V
Pressure setting
20pa~5000pa
Applicable pressure
Positive or negative pressure
Contact resistance
≤50mΩ
Maximum breakage pressure
10kpa
Operating temperature
-20℃~85℃
Connection size
Diameter 6mm
Insulation resistance
500V-DC-lasted 1min,≥5MΩ
Control Method
Open and close method
Electric strength
500V—- lasted 1min, no abnormality
Installation method
Recommended for vertical installation
Applicable medium
Non-hazardous gas...