Name
Current/Voltage Pressure Transmitter
Shell material
304 stainless steel
Core category
Ceramic core, diffused silicon oil-filled core (optional)
Pressure type
Gauge pressure type, absolute pressure type or sealed gauge pressure type
Range
-100kpa…0~20kpa…100MPA (optional)
Temperature compensation
-10-70°C
Precision
0.25%FS, 0.5%FS, 1%FS (comprehensive error including non-linear repeatability hysteresis)
Operating temperature
-40-125℃
Safety overload
2 times full sca...
Measuring medium
Various liquids, gases or vapors compatible with 304 and 316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Safety overload
2 times full scale pressure
output signal
4~20mADC (two-wire system), 0~10mADC, 0~20mADC, 0~5VDC, 1~5VDC, 0.5-4.5V, 0~10VDC (three-wire system)
Power supply
8~32VDC
Medium temperature
-20℃~85℃
Operating temperature
-40-125℃
Relative humidity
0%~100%
Rise Time
90% FS can be reached in l...
Electrical parameters
5(2.5)A 125/250V
Pressure setting
20pa~5000pa
Applicable pressure
Positive or negative pressure
Contact resistance
≤50mΩ
Maximum breakage pressure
10kpa
Operating temperature
-20℃~85℃
Connection size
Diameter 6mm
Insulation resistance
500V-DC-lasted 1min,≥5MΩ
Control Method
Open and close method
Electric strength
500V—- lasted 1min, no abnormality
Installation method
Recommended for vertical installation
Applicable medium
Non-hazardous gas...
Product model:MR-2260
Product Name: flow switch
Serial number
Project
Parameter
Remarks
1
Maximum switching current
0.5A(DC)
2
Maximum limit current
1A
3
Maximum contact resistance
100MΩ
4
Maximum load power
10W
50W optional
5
Maximum switching voltage
100V
6
Starting water flow
≥1.5L/min
7
Working flow range
2.0~15L/min
8
Working water pressure
0.1~0.8MPa
9
Maximum beari...
The automobile air conditioner pressure switch is a part to protect the air conditioner refrigeration, it can adjust the pressure in time.When the refrigerant pressure in the air conditioning system is too high or too low, the pressure switch is turned off, so that the compressor does not work (the pressure switch and other switches control the relay to control the compressor) and protect the system components from damage.Generally divided into two-state pressure switch and three-state pressu...
Name
Current/Voltage Pressure Transmitter
Shell material
304 stainless steel
Core category
Ceramic core, diffused silicon oil-filled core (optional)
Pressure type
Gauge pressure type, absolute pressure type or sealed gauge pressure type
Range
-100kpa…0~20kpa…100MPA (optional)
Temperature compensation
-10-70°C
Precision
0.25%FS, 0.5%FS, 1%FS (comprehensive error including non-linear repeatability hysteresis)
Operating temperature
-40-125℃
Safety overload
2 times full sca...
Name
Current/Voltage Pressure Transmitter
Shell material
304 stainless steel
Core category
Ceramic core, diffused silicon oil-filled core (optional)
Pressure type
Gauge pressure type, absolute pressure type or sealed gauge pressure type
Range
-100kpa…0~20kpa…100MPA (optional)
Temperature compensation
-10-70°C
Precision
0.25%FS, 0.5%FS, 1%FS (comprehensive error including non-linear repeatability hysteresis)
Operating temperature
-40-125℃
Safety overload
2 times full sca...