Measuring medium
Various liquids, gases or vapors compatible with 304 and 316 stainless steel
Measuring range
-100kpa…0~20kpa…100MPA (optional)
Safety overload
2 times full scale pressure
output signal
4~20mADC (two-wire system), 0~10mADC, 0~20mADC, 0~5VDC, 1~5VDC, 0.5-4.5V, 0~10VDC (three-wire system)
Power supply
8~32VDC
Medium temperature
-20℃~85℃
Operating temperature
-40-125℃
Relative humidity
0%~100%
Rise Time
90% FS can be reached in l...
Name
Current/Voltage Pressure Transmitter
Shell material
304 stainless steel
Core category
Ceramic core, diffused silicon oil-filled core (optional)
Pressure type
Gauge pressure type, absolute pressure type or sealed gauge pressure type
Range
-100kpa…0~20kpa…100MPA (optional)
Temperature compensation
-10-70°C
Precision
0.25%FS, 0.5%FS, 1%FS (comprehensive error including non-linear repeatability hysteresis)
Operating temperature
-40-125℃
Safety overload
2 times full sca...
Electrical parameters
5(2.5)A 125/250V
Pressure setting
20pa~5000pa
Applicable pressure
Positive or negative pressure
Contact resistance
≤50mΩ
Maximum breakage pressure
10kpa
Operating temperature
-20℃~85℃
Connection size
Diameter 6mm
Insulation resistance
500V-DC-lasted 1min,≥5MΩ
Control Method
Open and close method
Electric strength
500V—- lasted 1min, no abnormality
Installation method
Recommended for vertical installation
Applicable medium
Non-hazardous gas...
NAME
High And Low Pressure Pressure Switch/Two state pressure switch/Air conditioning refrigeration pressure switch/R134a pressure switch
MODEL
HFC-134a
PRESSURE VALUE
High pressure:3.14Mpa/2.65Mpa、Low pressure:0.196Mpa (This value can be customized according to your requirements )
Thread size
1/8 、 3/8 (Thread size can be customized according to your requirements )
Inserting type
Two inserting pieces( can be welded with the wire and has a sealing s...
1.Electrical parameters: 0.2A 24V DC T150; 0.5A 1A 2.5A 250VAC
2.Operating temperature: -40℃~ 120℃(No frost )
3.Connection size: The normal size is 1/8 or 1/4. Can be customized according to customer requirements
4.lifetime: 1 million times
5.Electrical life : 0.2A 24V DC 1 million times; 0.5A 12V DC 500,000 times; 1A 125V/250VAC 300,000 times
Pressure setting range psi
Pressure division psi
Pressure division kpa
Setting error psi
0.3~1psi
1~7kpa
±0.2psi
1.0~5psi
7~35kpa
±0....
Conventional
Number value
Remark
Pressure range
-100kpa…0~20kpa…100MPA (optional)
1MPa=10bar1bar≈14.5PSI1PSI=6.8965kPa1kgf/cm2 = 1atmosphere 1
atmosphere ≈ 98kPa
Overload pressure
2 times full scale pressure
Breaking pressure
3 times full scale pressure
Precision
0.25%FS、0.5%FS、1%FS (Higher precision can be customized )
Stability
0.2%FS/year
Operating temperature
-40-125℃
Compensation temperature
-10℃~70℃
Compatible media
All media compatible with 304/316...
Electrical parameters
5(2.5)A 125/250V
Pressure setting
20pa~5000pa
Applicable pressure
Positive or negative pressure
Contact resistance
≤50mΩ
Maximum breakage pressure
10kpa
Operating temperature
-20℃~85℃
Connection size
Diameter 6mm
Insulation resistance
500V-DC-lasted 1min,≥5MΩ
Control Method
Open and close method
Electric strength
500V—- lasted 1min, no abnormality
Installation method
Recommended for vertical installation
Applicable medium
Non-hazardous gas...
1. Product name: Pagoda Head Insert Type Water Pump Air Pump Pressure Switch, high quality through CE, ROSH certification
2. Pressure control range::0-10MPA
3. Pressure value: According to customer requirements
4. Interface type: pagoda head interface, can be equipped with air pipe
5. Interface material:Galvanized iron
6. Interface size: 6.35mm diameter
7. Connection mode: insert piece, insert piece can be welded with wire, wire tail can be equipped with connector.