One: Specifications and technical parameters
Brand: Anxing | Size: outer diameter 18/13.5 height 6.35/3.5 |
Supply voltage: 30Vdc, max | Sensitivity: 3mv/v |
Full scale output: ≥2mV/V | Bridge impedance: 10KQ± 30% |
Zero offset: <±0.2mV/V | Operating temperature: -40...135℃ |
Repeatability: ≤±0.2%FS | Safe overload pressure: ≥2 times the range |
C-100 | 0....100 | 250 |
C-200 | 0....200 | 350 |
C-300 | 0....300 | 450 |
C-400 | 0....400 | 550 |
C-500 | 0....500 | 650 |
C-600 | 0....600 | 750 |
Comprehensive accuracy (linearity + hysteresis) Repeatability ±1%FS(0--80℃) /±1.5%FS(-20--100℃) ±3%FS(-40--125℃) |
Measuring medium | Compatible with ceramic water, gas or liquid |
long term stability | ≤±0.5%FS/year |
Operating temperature | -40~125℃ |
Storage temperature | -40~130℃ |
Zero temperature coefficient | Typical: ±0.03%FS/℃; Maximum: ±0.05%FS/℃ |
Sensitivity temperature coefficient | Typical: ±0.03%FS/℃; Maximum: ±0.05%FS/℃ |
Name: Current Type Ceramic Pressure Module
Supply voltage: 8~32VDC
range:0~1...1.6...2...3...5...10...20...30MPA
output signal:4~20mA
Response time:<100MS
Electrical Specifications
Maximum excitation voltage 30Vdc
Bridge impedance 11KΩ±30%
Zero offset ≤±0.2mV/V
Insulation resistance ≥2 KV
Long-term stability of zero point @20 ℃ ±0.25%FS
Environmental Specifications:
Direct contact with liquid material 96% aluminum oxide
Operating temperature -40 up to ﹢135℃
Storage temperature -50 up to +150℃
Temperature Drift (Zero & Sensitivity) ≤±0.03%FS/℃
Relative humidity 0-99%
Sensor weight ≤ 7g (non-custom products)
Features
High safety and wide range of use
Excellent long-term stability
Effective temperature compensation
Operating temperature range -40 to +135℃
Can directly contact the measured medium, resistant to general acid and alkali (except hydrofluoric acid)
Affordable price Application fields: automobile, food, medicine, industrial automation, water pump, petroleum, chemical industry, starting equipment, hydraulic equipment, air conditioner, air compressor, etc.